Metal Smelting Base Plate Insulation Ain Substrate Module

Metal Smelting Base Plate Insulation Ain Substrate Module

Steel smelting foundation plate insulation AIN substrate module

We offer a broad selection of thyristor module, diode module, SCR module, electrical power module, quickly diode module, quickly thyristor module. a bridge rectifier,one-section bridge rectifier,three section bridge rectifier. 

 

Electrical power Module 

Characteristic

Isolated mounting foundation

CZPT common package 

Base plate insulation making use of AIN substrate   

CZPT compatible packaging                          

Low CZPT voltage drop                                          

High surge current Up to 5000V voltage CZPT on ask for

Press-pack construction, exceptional temperature qualities, and power biking capability

Underneath 350A modules are all forced air cooling,  above 400A modules, air-cooled and water-cooled optional

 

Application 

For motor drives, electrical power provide, electrical power transmission and distribution, railway transportation, steel smelting, 

equipment manufacturing, welding equipment, chemical market, renewable vitality.

Common Purposes:

  • welding device
  • AC&DC motor handle
  • Numerous rectifying power provide
  • CZPT heating manage
  • Dimming
  • Contactless swap
  • Motor gentle commence
  • Static reactive payment
  • CZPT welding equipment
  • Frequency converter
  • UPS electricity offer
  • Battery charge and discharge

Datasheet
 

Type IT(AV)   VDRM
VRRM
ITSM   IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tj Fig
A V Ax103 mA A/μs V/μs mA v mA V ºC/ W ºC mm
MTx25 25 600-1800 .55  ten >50 >800 <50 <2 <50 .90 nine.80 .ninety five a hundred twenty five A
MTx40 forty one.00  10 >50 <150 <2 <150 .86 5.sixty .sixty eight A
MTx55 fifty five one.25  10 >50 <150 <2 <150 .87 three.70 .fifty four A
MTx70 70 1.60  15 >50 <150 <2 <150 .ninety two.65 .forty two A
MTx90 ninety 2.00 15 >100 <150 <2 <150 .90 2.84 .30 A,B
MTx110 110 2.40  20 >100 <150 <2 <150 .80 2.34 .26 A,B
MTx130 one hundred thirty three.60 thirty >100 <150 <3 <150 .ninety 2.12 .twenty C
MTx160 a hundred and sixty 5.40  thirty >100 <150 <3 <150 .90 one.fifty three .17 C
MTx200 two hundred 7.20  thirty >100 <200 <3 <200 .eighty five one.34 .13 D
MTx250 250 8.50  30 >100 <200 <3 <200 .85 .ninety .12 D
MTx300 300 nine.30  40 >100 <200 <3 <200 .85 .seventy five .10 D
MTx350 350 eleven.0  forty >100 <200 <3 <200 .ninety .50 .09 F
MTx400 four hundred twelve.0  50 >100 <200 <3 <200 .eighty five .forty nine .09  F,N
MTx500 500 14.5  fifty >100 <200 <3 <200 .eighty five .40 .08  F,N
MTx600 600 17.four 50 >100 <200 <3 <200 .86 .45 .075 H
MTx800 800 23.2 50 >100 <200 <3 <200 .9 .fifty .065 J
 MTx1000
*
one thousand 28. 50 >100 <200 <3 <200 .87 .forty five .06 J
*MTx500 five hundred twelve. 50 >100 <200 <3 <200 .8 .sixty four .085 G
*MTx600
*
 
600 15. 50 >100 <200 <3 <200 .eighty five .5 .07 I
*MTx800 800 18. fifty >100 <200 <3 <200 .9 .four .05 K
     
MTC                    MTA                  MTK                    MTX              MT

Observe :  If VDRM/VRRM ≥2500V , Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V remember to make contact with us         Tj=125ºC  Tc=eighty five ºC     * Water cooling and Tc=55ºC

 

Type IF(AV)   VRRM IFSM   IRRM VFO rF Rth(j-c) VISO Tj Fig
A V Ax10three mA V ºC/ W V ºC mm
MDx25 twenty five 600-1800 .65  10 .80 10.9 one.twenty five 2500 a hundred and fifty A
MDx40 forty one.00  ten .80 six.00 .90 A
MDx55 55 one.30  ten .eighty 3.eighty .70 A
MDx70 70 1.80  fifteen .76 2.70 .fifty six A
MDx90 90 two.thirty fifteen .seventy seven 2.20 .forty five A,B
MDx110 110 two.60  20 .eighty 1.75 .35 A,B
MDx130 130 3.90 thirty .80 1.forty five .thirty C
MDx160 160 6.00  thirty .79 1.35 .23 C
MDx200 two hundred eight.00  thirty .seventy six .90 .fourteen D
MDx250 250 eleven.0  30 .78 .88 .14 D
MDx300 300 twelve.5  40 .80 .sixty five .thirteen D
MDx350 350 15.0  forty .eighty .61 .10  F
MDx400 four hundred 17.0  50 .seventy eight .fifty .10 F,N
MDx500 500 19.
 
fifty .75 .32 .09 F,N
 MDx600 600 twenty.eight 50 .eighty two .40 .08 H
 MDx800 800 22. 50 .78 .25
five
.07 J
 MDx1000 one thousand twenty five. fifty .75 .forty five .065 J
*MDx500 500 13. 50 .78 .50
five
.ten G
*MDx600 600 15. 50 .75 .45 .09 I
*MDx800 800 19. fifty .seventy five .34 .08 K
         
MDC                        MDA                     MDK                      MD

Notice :  If VDRM/VRRM ≥2500V , Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V make sure you speak to manufacturing unit          Tc=100 ºC   * Drinking water cooling and Tc=85ºC
 

Variety IT(AV)   VDRM
VRRM
ITSM 
 IFSM 
IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tj Fig
A V Ax10three mA A/μs V/μs mA v mA V ºC/ W ºC mm
MFx25 25 600-1800 .55  10 >50 >800 <50 <2 <50 .ninety nine.80 .ninety five one hundred twenty five A
MFx40 40 one.00  ten >50 <150 <2 <150 .86 five.60 .68 A
MFx55 fifty five 1.25  ten >50 <150 <2 <150 .87 3.70 .fifty four A
MFx70 70 1.60  15 >50 <150 <2 <150 .90 2.sixty five .forty two A
MFx90 90 two.00 fifteen >100 <150 <2 <150 .90 two.84 .30 A,B
MFx110 110 2.40  20 >100 <150 <2 <150 .eighty 2.34 .26 A,B
MFx130 a hundred thirty 3.60 thirty >100 <150 <3 <150 .90 two.twelve .twenty C
MFx160 160 5.40  thirty >100 <150 <3 <150 .ninety one.53 .17 C
MFx200 two hundred seven.20  30 >100 <200 <3 <200 .85 one.34 .13 D
MFx250 250 8.50  30 >100 <200 <3 <200 .eighty five .90 .12 D
MFx300 300 9.30  40 >100 <200 <3 <200 .eighty five .seventy five .ten D
MFx350 350 11.0  40 >100 <200 <3 <200 .ninety .fifty .09 F
MFx400 four hundred twelve.0  50 >100 <200 <3 <200 .eighty five .forty nine .09  F,N
MFx500 500 fourteen.5  fifty >100 <200 <3 <200 .85 .40 .08  F,N
MFx600 600 seventeen.four 50 >100 <200 <3 <200 .86 .45 .075 H
MFx800 800 23.2 50 >100 <200 <3 <200 .nine .50 .065 J
MFx1000 one thousand 28. 50 >100 <200 <3 <200 .87 .45 .06 J
*MFx500 500 twelve. 50 >100 <200 <3 <200 .8 .sixty four .085 G
*MFx600 600 fifteen. fifty >100 <200 <3 <200 .85 .5 .07 I
*MFx800 800 18. 50 >100 <200 <3 <200 .nine .4 .05 K
                 
MFC                                MFA                                MFK                    

Observe : If VDRM/VRRM ≥2500V , Viso (AC)>3000V  otherwise =2500V, For module with VDRM/VRRM  from 2500 to 5000V you should get in touch with us         Tj=125ºC  Tc=eighty five ºC     * Drinking water cooling and Tc=55ºC
MDS

Kind IO   VRRM IFSM   IRRM VFO rF Rth(j-c) VISO Tj Fig
A V Ax103 mA V ºC/ W V ºC mm
MDS75 seventy five 600-1800 1.00  ten .80 4.70 .36 2500 a hundred and fifty L
MDS100 100 1.50  ten .80 four.33 .29 L
MDS160 160 two.60  10 .80 one.80 .18 M
MDS200 200 three.20  15 .eighty one.sixty .15 M
MDS

 Note:Tc=100 ºC
MKC  MHC

IT(AV)   VDRM
VRRM
ITSM  IDRM
IRRM
di/dt dv/dt IGT VGT IH VTO rT Rth(j-c) Tq Tj Fig
A V Ax10three mA A/μs V/μs mA v mA V ºC/ W μs ºC mm
160 600-1600 4.30  thirty >200 >800 <150 <3 <150 .86 1.66 .fourteen 15-35 a hundred and fifteen D
200 five.60  30 >200 <200 <3 <200 .ninety one.17 .10 15-35 F
three hundred seven.80  40 >200 <200 <3 <200 .88 .80 .07 fifteen-35 H

 MZC

IT(AV)   VRRM IFSM  IRRM VFO RF Rth(j-c) Trr Tj Fig
A V Ax103 mA V ºC/ W μs ºC mm
a hundred and sixty 600-1600 four.50 thirty .85 one.40 .18 two. a hundred and forty D
two hundred 6.00 30 .88 .ninety five .fourteen 3. F
300 8.30 40 .86 .sixty .ten 4. H

    

                       
         MKC                           MHC                         MZC

Observe:  MKC MHC @ Tc=85ºC     MZC @Tc=100ºC   VISO (AC)>2500V

Define dimensions:

Company Certification

Factory environment screen:

Packing

Relying on the merchandise size, but all merchandise with normal, protected packaging or CZPT.

Shipping

We will ship the things within 3 doing work times after the payment obtained.

We can ship to you by DHL/TNT/UPS/EMS/FedEx…

Pls speak to us directly and we will ship as your demands.

 

Metal Smelting Base Plate Insulation Ain Substrate Module