Product Description
Product Description
Three-Phase Motor is an electric motor driven by a three-phase AC power source.
They are widely used as power sources for industrial equipment and machinery. Also called three-phase induction motors (induction motors), they are generally powered by a three-phase AC power supply of 200 V, 110V, 380V and so on.
Three-Phase Motors consist of a stator, rotor, output shaft, flange bracket, and ball bearings.
YS (MS), YE3, Y4 Motor Series
YS (MS), YE3, YE4 series three-phase asynchronous motors with Aluminum housing adopted the newest design and high quality material.lt is conformity with the IEC 34-1 standards. The efficiency of the motors can meet EFF2 and EFF1 if requested. That good features: perfect performance low noises light vibration, reliable running, good appearance, small volume and light weight.
YEJ Brake Motor Series
Brake motor is made of 2 parts: three-phase asynchronous motors and brake, it belongs to three-phase-asynchronous motor derived series. Manual brake release and bolt release are 2 forms of brake. Brake is the main components of the brake motor. Its working power divided into 2 categories: One is AC braking, the other is DC braking. Our company produces brake motors are DC brake motors, the advantage of the braking torque is below, easy installation, braking response speed, high reliability, versatility and other advantages.
To the Ac power to the brake coil is provided with suction cups for low voltage winding rated DC voltage. A single-phase AC power is rectified then supply to a sucker winding to make it work so the brake motor terminal box fitted with a rectifier, wiring diagram below.Brake motor braking time (t) is the time from the motor and brake stopping the power to the shaft completely stopped, under normal circumstances, for 63 to 880 frame size motor, the braking time is 0.5 seconds. For o-132 frame size motor the braking time is 1 second, For 160 to180 frame size motor, the braking time is 2 seconds.
YVP Frequency Conversion Motor Series
YVP speed has become the popular way, can be widely used in various industries continuously variable transmission.
In the variable frequency motor speed control system, using power electronic inverter as a power supply is inevitable that there will be high harmonics, harmonic greater impact on the motor. Mainly reflected in the magnetic circuit and the circuit harmonic magnetic potential harmonic currents. Different amplitudes and frequencies of harmonic currents and magnetic flux will cause the motor stator copper loss rotor aluminum consumption. These losses of the motor efficiency and power factor reduction, the majority of these losses into heat, causing additional heating of the motor, causing the motor temperature increases, the increase in temperature generally 10~20%. As a result of electromagnetic interference power, conduction and radiation, the stator winding insulation aging, resulting in deterioration of the common-mode voltage and leakage current of accelerated beaning, bearing perishable, while the motor screaming. Since harmonic electromagnetic torque constant harmonic electromagnetic torque and vibration harmonic MMFs and rear rotor harmonic current synthesis. The torque of the motor torque will generate pulsating issued, so that the motor speed vibration is low.
Our produce YS, IE2, IE3, IE4 Series Universal three-phase asynchronous motor design, our main consideration is the motor overload, starting performance, efficiency and power factor. Another major consideration for non-sinusoidal motor power adaptability. Suppose the influence of higher harmonic current to the motor. Since the motor is increased when the working
Temperature of the low-frequency region, class F insulation dl ass above, the use of polymer insulation materials and vacuum pressure impregnation process, and the use of special insulation structure. Ln order to reduce the electromagnetic torque ripple, improve the precision mechanical parts to improve the quality level constant. high-precision bearing mute. n order to eliminate vibration motor, the motor structure to strengthen the overall design.
Operating conditions:
Ambient temperature: | -15ºC<0<40ºC | Duty: | S1 (continuous) |
Altitude: | not exceed1000m | Insulation class: | B/F/H |
Rated voltage: | 380V, 220V-760Vis available | Protection class: | lP54/IP55 |
Rated frequency: | 50HZ/60HZ | Cooling method: | IC0141 |
Production Flow
Product Overall & Installation Dimensions:
YS/MS Series:
Frame size | lnstallation Dimensions B3 (mm ) | lnstallation Dimensions B5 (mm ) | lnstallation Dimension B14 (mm ) | Mounting Dimensions (mm ) | ||||||||||||||||||||
A | B | C | D | E | F | G | H | K | M | N | P | S | T | M | N | P | S | T | AB | AC | AD | HD | L | |
56 | 90 | 71 | 36 | 9 | 20 | 3 | 7.2 | 56 | 5.8 | 100 | 80 | 120 | 7 | 3 | 65 | 50 | 80 | M5 | 2.5 | 110 | 120 | 100 | 155 | 195 |
63 | 100 | 80 | 40 | 11 | 23 | 4 | 8.5 | 63 | 7 | 115 | 95 | 140 | 10 | 3 | 75 | 60 | 90 | M5 | 2.5 | 125 | 130 | 100 | 165 | 215 |
71 | 112 | 90 | 45 | 14 | 30 | 5 | 11 | 71 | 7 | 130 | 110 | 160 | 10 | 3.5 | 85 | 70 | 105 | M6 | 2.5 | 140 | 150 | 110 | 185 | 246 |
80 | 125 | 100 | 50 | 19 | 40 | 6 | 15.5 | 80 | 10 | 165 | 130 | 200 | 12 | 3.5 | 100 | 80 | 120 | M6 | 3 | 160 | 170 | 135 | 215 | 285 |
90S | 140 | 100 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 12 | 3.5 | 115 | 95 | 140 | M8 | 3 | 178 | 185 | 137 | 226 | 335 |
90L | 140 | 125 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 12 | 3.5 | 115 | 95 | 140 | M8 | 3 | 178 | 185 | 137 | 226 | 335 |
100L | 160 | 140 | 63 | 28 | 60 | 8 | 24 | 100 | 12 | 215 | 180 | 250 | 15 | 4 | 130 | 110 | 160 | M8 | 3.5 | 206 | 206 | 150 | 250 | 376 |
112M | 190 | 140 | 70 | 28 | 60 | 8 | 24 | 112 | 12 | 215 | 180 | 250 | 15 | 4 | 130 | 110 | 160 | M8 | 3.5 | 222 | 228 | 170 | 285 | 400 |
132S | 216 | 140 | 89 | 38 | 80 | 10 | 33 | 132 | 12 | 265 | 230 | 300 | 15 | 4 | 165 | 130 | 200 | M10 | 4 | 257 | 267 | 190 | 325 | 460 |
132M | 216 | 178 | 89 | 38 | 80 | 10 | 33 | 132 | 12 | 265 | 230 | 300 | 15 | 4 | 165 | 130 | 200 | M10 | 4 | 257 | 267 | 190 | 325 | 500 |
160M | 254 | 210 | 108 | 42 | 110 | 12 | 37 | 160 | 15 | 300 | 250 | 350 | 15 | 5 | 215 | 180 | 250 | M12 | 4 | 320 | 330 | 255 | 420 | 615 |
160L | 254 | 254 | 108 | 42 | 110 | 12 | 37 | 160 | 15 | 300 | 250 | 350 | 15 | 5 | 215 | 180 | 250 | M12 | 4 | 320 | 330 | 255 | 420 | 675 |
180M | 279 | 241 | 121 | 48 | 110 | 14 | 42.5 | 180 | 15 | 300 | 250 | 350 | 19 | 5 | 265 | 230 | 300 | M15 | 4 | 355 | 380 | 280 | 455 | 700 |
180L | 279 | 279 | 121 | 48 | 110 | 14 | 42.5 | 180 | 15 | 300 | 250 | 350 | 19 | 5 | 265 | 230 | 300 | M15 | 4 | 355 | 380 | 280 | 455 | 740 |
YE3, YE4 Series:
Frame size | lnstallation Dimensions B3 (mm ) | lnstallation Dimensions B5 (mm ) | lnstallation Dimension B14 (mm ) | Mounting Dimensions (mm ) | ||||||||||||||||||||
A | B | C | D | E | F | G | H | K | M | N | P | S | T | M | N | P | S | T | AB | AC | AD | HD | L | |
56 | 90 | 71 | 36 | 9 | 20 | 3 | 7.2 | 56 | 5.8 | 100 | 80 | 120 | 7 | 3 | 65 | 50 | 80 | M5 | 2.5 | 110 | 120 | 100 | 155 | 195 |
63 | 100 | 80 | 40 | 11 | 23 | 4 | 8.5 | 63 | 7 | 115 | 95 | 140 | 10 | 3 | 75 | 60 | 90 | M5 | 2.5 | 125 | 130 | 100 | 165 | 215 |
71 | 112 | 90 | 45 | 14 | 30 | 5 | 11 | 71 | 7 | 130 | 110 | 160 | 10 | 3.5 | 85 | 70 | 105 | M6 | 2.5 | 140 | 150 | 110 | 185 | 246 |
80 | 125 | 100 | 50 | 19 | 40 | 6 | 15.5 | 80 | 10 | 165 | 130 | 200 | 12 | 3.5 | 100 | 80 | 120 | M6 | 3 | 160 | 170 | 145 | 215 | 305 |
90S | 140 | 100 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 12 | 3.5 | 115 | 95 | 140 | M8 | 3 | 178 | 185 | 165 | 226 | 360 |
90L | 140 | 125 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 12 | 3.5 | 115 | 95 | 140 | M8 | 3 | 178 | 185 | 165 | 226 | 385 |
100L | 160 | 140 | 63 | 28 | 60 | 8 | 24 | 100 | 12 | 215 | 180 | 250 | 15 | 4 | 130 | 110 | 160 | M8 | 3.5 | 270 | 206 | 175 | 250 | 445 |
112M | 190 | 140 | 70 | 28 | 60 | 8 | 24 | 112 | 12 | 215 | 180 | 250 | 15 | 4 | 130 | 110 | 160 | M8 | 3.5 | 270 | 228 | 190 | 285 | 455 |
132S | 216 | 140 | 89 | 38 | 80 | 10 | 33 | 132 | 12 | 265 | 230 | 300 | 15 | 4 | 165 | 130 | 200 | M10 | 4 | 270 | 267 | 220 | 325 | 475 |
132M | 216 | 178 | 89 | 38 | 80 | 10 | 33 | 132 | 12 | 265 | 230 | 300 | 15 | 4 | 165 | 130 | 200 | M10 | 4 | 270 | 267 | 220 | 325 | 570 |
160M | 254 | 210 | 108 | 42 | 110 | 12 | 37 | 160 | 15 | 300 | 250 | 350 | 15 | 5 | 215 | 180 | 250 | M12 | 4 | 320 | 330 | 260 | 420 | 655 |
160L | 254 | 254 | 108 | 42 | 110 | 12 | 37 | 160 | 15 | 300 | 250 | 350 | 15 | 5 | 215 | 180 | 250 | M12 | 4 | 320 | 330 | 260 | 420 | 685 |
180M | 279 | 241 | 121 | 48 | 110 | 14 | 42.5 | 180 | 15 | 300 | 250 | 350 | 19 | 5 | 265 | 230 | 300 | M15 | 4 | 360 | 380 | 305 | 455 | 705 |
180L | 279 | 279 | 121 | 48 | 110 | 14 | 42.5 | 180 | 15 | 300 | 250 | 350 | 19 | 5 | 265 | 230 | 300 | M15 | 4 | 360 | 380 | 305 | 455 | 745 |
YEJ B3 Series H63-180:
Frame size | Installation Dimensions (mm) | ||||||||||||
A | B | C | D | E | F | G | H | K | AB | AC | HD | L | |
63 | 100 | 80 | 40 | Φ11 | 23 | 4 | 12.5 | 63 | Φ7 | 135 | 120×120 | 167 | 255 |
71 | 112 | 90 | 45 | Φ14 | 30 | 5 | 16 | 71 | Φ7 | 137 | 130×130 | 178 | 305 |
80M | 125 | 100 | 50 | Φ19 | 40 | 6 | 21.5 | 80 | Φ10 | 155 | 145×145 | 190 | 340 |
90S | 140 | 100 | 56 | Φ24 | 50 | 8 | 27 | 90 | Φ10 | 175 | 160×160 | 205 | 400 |
90L | 140 | 125 | 56 | Φ24 | 50 | 8 | 27 | 90 | Φ10 | 175 | 160×160 | 205 | 400 |
100L | 160 | 140 | 63 | Φ28 | 60 | 8 | 31 | 100 | Φ12 | 200 | 185×185 | 240 | 440 |
112M | 190 | 140 | 70 | Φ28 | 60 | 8 | 31 | 112 | Φ12 | 230 | 200×200 | 270 | 480 |
132S | 216 | 140 | 89 | Φ38 | 80 | 10 | 41 | 132 | Φ12 | 270 | 245×245 | 315 | 567 |
132M | 216 | 178 | 89 | Φ38 | 80 | 10 | 41 | 132 | Φ12 | 270 | 245×245 | 315 | 567 |
160M | 254 | 210 | 108 | Φ42 | 110 | 12 | 45 | 160 | Φ14.5 | 320 | 335×335 | 450 | 780 |
160L | 254 | 254 | 108 | Φ42 | 110 | 12 | 45 | 160 | Φ14.5 | 320 | 335×335 | 450 | 780 |
180M | 279 | 241 | 121 | Φ48 | 110 | 14 | 51.5 | 180 | Φ14.5 | 355 | 370×370 | 500 | 880 |
180L | 279 | 279 | 121 | Φ48 | 110 | 14 | 51.5 | 180 | Φ14.5 | 355 | 370×370 | 500 | 880 |
YEJ B5 Series H63-180:
Frame size | Installation Dimensions (mm) | |||||||||||
D | E | F | G | M | N | P | S | T | AC | HD | L | |
63 | Φ11 | 23 | 4 | 12.5 | 115 | 95 | 140 | 10 | 3 | 120×120 | 104 | 255 |
71 | Φ14 | 30 | 5 | 16 | 130 | 110 | 160 | 10 | 3 | 130×130 | 107 | 305 |
80M | Φ19 | 40 | 6 | 21.5 | 165 | 130 | 200 | 12 | 3.5 | 145×145 | 115 | 340 |
90S | Φ24 | 50 | 8 | 27 | 165 | 130 | 200 | 12 | 3.5 | 160×160 | 122 | 400 |
90L | Φ24 | 50 | 8 | 27 | 165 | 130 | 200 | 12 | 3.5 | 160×160 | 122 | 400 |
100L | Φ28 | 60 | 8 | 31 | 215 | 180 | 250 | 14.5 | 4 | 185×185 | 137 | 440 |
112M | Φ28 | 60 | 8 | 31 | 215 | 180 | 250 | 14.5 | 4 | 200×200 | 155 | 480 |
132S | Φ38 | 80 | 10 | 41 | 265 | 230 | 300 | 14.5 | 4 | 245×245 | 180 | 567 |
132M | Φ38 | 80 | 10 | 41 | 265 | 230 | 300 | 14.5 | 4 | 245×245 | 180 | 567 |
160M | Φ42 | 110 | 12 | 45 | 300 | 250 | 350 | 18.5 | 5 | 320×320 | 290 | 780 |
160L | Φ42 | 110 | 12 | 45 | 300 | 250 | 350 | 18.5 | 5 | 320×320 | 290 | 780 |
180M | Φ48 | 110 | 14 | 51.5 | 300 | 250 | 350 | 18.5 | 5 | 360×360 | 340 | 880 |
180L | Φ48 | 110 | 14 | 51.5 | 300 | 250 | 350 | 18.5 | 5 | 360×360 | 340 | 880 |
YEJ B14 Series H63-112:
Frame size | Installation Dimensions (mm) | |||||||||||
D | E | F | G | M | N | P | S | T | AC | HD | L | |
63 | Φ11 | 23 | 4 | 12.5 | 75 | 60 | 90 | M5 | 2.5 | 120×120 | 104 | 255 |
71 | Φ14 | 30 | 5 | 16 | 85 | 70 | 105 | M6 | 2.5 | 130×130 | 107 | 305 |
80 | Φ19 | 40 | 6 | 21.5 | 100 | 80 | 110 | M6 | 3 | 145×145 | 115 | 340 |
90S | Φ24 | 50 | 8 | 27 | 115 | 95 | 120 | M8 | 3 | 160×160 | 122 | 400 |
90L | Φ24 | 50 | 8 | 27 | 115 | 95 | 120 | M8 | 3 | 160×160 | 122 | 400 |
100L | Φ28 | 60 | 8 | 31 | 130 | 110 | 155 | M8 | 3.5 | 185×185 | 137 | 440 |
112M | Φ28 | 60 | 8 | 31 | 130 | 110 | 160 | M8 | 3.5 | 200×200 | 155 | 480 |
YVP B3 Series H63-180:
Frame size | Installation Dimensions (mm) | ||||||||||||
A | B | C | D | E | F | G | H | K | AB | AC | HD | L | |
63 | 100 | 80 | 40 | Φ11 | 23 | 4 | 12.5 | 63 | 7 | 135 | 120×120 | 167 | 260 |
71 | 112 | 90 | 45 | Φ14 | 30 | 5 | 16 | 71 | 7 | 137 | 130×130 | 178 | 295 |
80 | 125 | 100 | 50 | Φ19 | 40 | 6 | 21.5 | 80 | 10 | 155 | 145×145 | 190 | 340 |
90S | 140 | 100 | 56 | Φ24 | 50 | 8 | 27 | 90 | 10 | 175 | 160×160 | 205 | 390 |
90L | 140 | 125 | 56 | Φ24 | 50 | 8 | 27 | 90 | 10 | 175 | 160×160 | 205 | 400 |
100L | 160 | 140 | 63 | Φ28 | 60 | 8 | 31 | 100 | 12 | 200 | 185×185 | 240 | 430 |
112M | 190 | 140 | 70 | Φ28 | 60 | 8 | 31 | 112 | 12 | 230 | 200×200 | 270 | 460 |
132S | 216 | 140 | 89 | Φ38 | 80 | 10 | 41 | 132 | 12 | 270 | 245×245 | 315 | 525 |
132M | 216 | 178 | 89 | Φ38 | 80 | 10 | 41 | 132 | 12 | 270 | 245×245 | 315 | 525 |
160M | 254 | 210 | 108 | Φ42 | 110 | 12 | 45 | 160 | 14.5 | 320 | 335×335 | 450 | 850 |
160L | 254 | 254 | 108 | Φ42 | 110 | 12 | 45 | 160 | 14.5 | 320 | 335×335 | 450 | 870 |
180M | 279 | 241 | 121 | Φ48 | 110 | 14 | 51.5 | 180 | 14.5 | 355 | 370×370 | 500 | 880 |
180L | 279 | 279 | 121 | Φ48 | 110 | 14 | 51.5 | 180 | 14.5 | 355 | 370×370 | 500 | 980 |
YVP B5 Series H63-180:
C | Installation Dimensions (mm) | |||||||||||
D | E | F | G | M | N | P | S | T | AC | HD | L | |
63 | Φ11 | 23 | 4 | 12.5 | 115 | 95 | 140 | 10 | 3 | 120×120 | 104 | 260 |
71 | Φ14 | 30 | 5 | 16 | 130 | 110 | 160 | 10 | 3.5 | 130×130 | 107 | 295 |
80M | Φ19 | 40 | 6 | 21.5 | 165 | 130 | 200 | 12 | 3.5 | 145×145 | 115 | 340 |
90S | Φ24 | 50 | 8 | 27 | 165 | 130 | 200 | 12 | 3.5 | 160×160 | 122 | 390 |
90L | Φ24 | 50 | 8 | 27 | 165 | 130 | 200 | 12 | 3.5 | 160×160 | 122 | 400 |
100L | Φ28 | 60 | 8 | 31 | 215 | 180 | 250 | 14.5 | 4 | 185×185 | 137 | 430 |
112M | Φ28 | 60 | 8 | 31 | 215 | 180 | 250 | 14.5 | 4 | 200×200 | 155 | 460 |
132S | Φ38 | 80 | 10 | 41 | 265 | 230 | 300 | 14.5 | 4 | 245×245 | 180 | 525 |
132M | Φ38 | 80 | 10 | 41 | 265 | 230 | 300 | 14.5 | 4 | 245×245 | 180 | 252 |
160M | Φ42 | 110 | 12 | 45 | 300 | 250 | 350 | 18.5 | 5 | 335×335 | 290 | 850 |
160L | Φ42 | 110 | 12 | 45 | 300 | 250 | 350 | 18.5 | 5 | 335×335 | 290 | 870 |
180M | Φ48 | 110 | 14 | 51.5 | 300 | 250 | 350 | 18.5 | 5 | 370×370 | 340 | 880 |
180L | Φ48 | 110 | 14 | 51.5 | 300 | 250 | 350 | 18.4 | 5 | 370×370 | 340 | 980 |
YVP B14 Series H63-112:
Frame size | Installation Dimensions (mm) | |||||||||||
D | E | F | G | M | N | P | S | T | AC | HD | L | |
63 | Φ11 | 23 | 4 | 12.5 | 75 | 60 | 90 | M5 | 2.5 | 120×120 | 104 | 260 |
71 | Φ14 | 30 | 5 | 16 | 85 | 70 | 105 | M6 | 2.5 | 130×130 | 107 | 295 |
80 | Φ19 | 40 | 6 | 21.5 | 100 | 80 | 110 | M6 | 3 | 145×145 | 115 | 340 |
90S | Φ24 | 50 | 8 | 27 | 115 | 95 | 120 | M8 | 3 | 160×160 | 122 | 390 |
90L | Φ24 | 50 | 8 | 27 | 115 | 95 | 120 | M8 | 3 | 160×160 | 122 | 400 |
100L | Φ28 | 60 | 8 | 31 | 130 | 110 | 155 | M8 | 3.5 | 185×185 | 137 | 430 |
112M | Φ28 | 60 | 8 | 31 | 130 | 110 | 160 | M8 | 3.5 | 200×200 | 155 | 460 |
Product Parameters
YS/MS Series:
TYPE | RATED OUTPUT | RATED SPEED |
EFFICIENCY | POWER FOCTOR |
RATED CURRENT |
RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TOROUE | LOCKED ROTOR TORQUE | |
RATED TORQUE | RATED TORQUE | RATED CURRENT | ||||||||
KW | HP | rpm | η%(IE2) | cosφ | A | Nm | Ts/Tn | Tmax/Tn | IS/In | |
YS-5612 | 0.09 | 1/8 | 2680 | 62.0 | 0.68 | 0.32 | 0.307 | 2.3 | 2.3 | 6.0 |
YS-5622 | 0.12 | 1/6 | 2660 | 67.0 | 0.71 | 0.38 | 0.410 | 2.3 | 2.3 | 6.0 |
YS-6312 | 0.18 | 1/4 | 2710 | 69.0 | 0.75 | 0.53 | 0.614 | 2.3 | 2.3 | 6.0 |
YS-6322 | 0.25 | 1/3 | 2730 | 72.0 | 0.78 | 0.68 | 0.853 | 2.3 | 2.3 | 6.0 |
YS-7112 | 0.37 | 1/2 | 2760 | 73.5 | 0.80 | 0.96 | 1.260 | 2.3 | 2.3 | 6.0 |
YS-7122 | 0.55 | 3/4 | 2770 | 75.5 | 0.82 | 1.35 | 1.880 | 2.3 | 2.3 | 6.0 |
YS-8012 | 0.75 | 1.0 | 2770 | 76.5 | 0.85 | 1.75 | 2.560 | 2.2 | 2.3 | 6.0 |
YS-8571 | 1.10 | 1.5 | 2800 | 77.0 | 0.85 | 2.55 | 3.750 | 2.2 | 2.3 | 7.0 |
YS-90S-2 | 1.50 | 2.0 | 2840 | 78.5 | 0.85 | 3.42 | 5.040 | 2.2 | 2.3 | 7.0 |
YS-90L-2 | 2.20 | 3.0 | 2840 | 81.0 | 0.86 | 4.80 | 7.400 | 2.2 | 2.3 | 7.0 |
YS-100L-2 | 3.00 | 4.0 | 2890 | 84.6 | 0.87 | 6.17 | 9.910 | 2.2 | 2.3 | 7.8 |
YS-5614 | 0.06 | 1/12 | 1320 | 56.0 | 0.58 | 0.28 | 0.410 | 2.4 | 2.4 | 6.0 |
YS-5624 | 0.09 | 1/8 | 1320 | 58.0 | 0.61 | 0.39 | 0.614 | 2.4 | 2.4 | 6.0 |
YS-6314 | 0.12 | 1/6 | 1350 | 60.0 | 0.63 | 0.48 | 0.819 | 2.4 | 2.4 | 6.0 |
YS-6324 | 0.18 | 1/4 | 1350 | 64.0 | 0.66 | 0.65 | 1.230 | 2.4 | 2.4 | 6.0 |
YS-7114 | 0.25 | 1/3 | 1350 | 67.0 | 0.68 | 0.83 | 1.710 | 2.4 | 2.4 | 6.0 |
YS-7124 | 0.37 | 1/2 | 1350 | 69.5 | 0.72 | 1.12 | 2.520 | 2.4 | 2.4 | 6.0 |
YS-8014 | 0.55 | 3/4 | 1380 | 73.5 | 0.73 | 1.56 | 3.750 | 2.4 | 2.4 | 6.0 |
YS-8571 | 0.75 | 1.0 | 1390 | 75.5 | 0.75 | 2.01 | 5.120 | 2.3 | 2.4 | 6.5 |
YS-90S-4 | 1.10 | 1.5 | 1400 | 78.0 | 0.78 | 2.75 | 7.400 | 2.3 | 2.4 | 6.5 |
YS-90L-4 | 1.50 | 2.0 | 1400 | 79.0 | 0.79 | 3.65 | 10.100 | 2.3 | 2.4 | 6.5 |
YS-100L1-4 | 2.20 | 3.0 | 1440 | 84.3 | 0.81 | 4.90 | 14.600 | 2.3 | 2.3 | 7.6 |
YS-100L2-4 | 3.00 | 4.0 | 1440 | 85.5 | 0.82 | 6.50 | 19.900 | 2.3 | 2.3 | 7.6 |
YS-7116 | 0.18 | 1/4 | 910 | 59.0 | 0.61 | 0.76 | 1.890 | 2.0 | 2.0 | 5.5 |
YS-7126 | 0.25 | 1/3 | 910 | 63.0 | 0.62 | 0.97 | 2.260 | 2.0 | 2.0 | 5.5 |
YS-8016 | 0.37 | 1/2 | 910 | 68.0 | 0.62 | 1.33 | 3.880 | 2.0 | 2.0 | 5.5 |
YS-8026 | 0.55 | 3/4 | 910 | 71.0 | 0.64 | 1.84 | 5.770 | 2.0 | 2.0 | 5.5 |
YS-90S-6 | 0.75 | 1.0 | 920 | 73.0 | 0.68 | 2.30 | 7.790 | 2.0 | 2.1 | 5.5 |
YS-90L-6 | 1.10 | 1.5 | 920 | 74.0 | 0.70 | 3.23 | 11.400 | 2.0 | 2.1 | 6.0 |
YS-100L-6 | 1.50 | 2.0 | 940 | 79.0 | 0.75 | 3.38 | 15.200 | 2.0 | 2.1 | 6.5 |
YS-711-8 | 0.09 | 0.12 | 600 | 40.0 | 0.57 | 0.60 | 1.950 | 1.8 | 1.9 | 2.8 |
YS-712-8 | 0.12 | 0.18 | 600 | 45.0 | 0.57 | 0.71 | 2.160 | 1.8 | 1.9 | 2.8 |
YS-801-8 | 0.18 | 0.25 | 645 | 51.0 | 0.61 | 0.88 | 2.490 | 1.8 | 2.0 | 3.3 |
YS-802-8 | 0.25 | 0.37 | 645 | 54.0 | 0.61 | 1.15 | 3.640 | 1.8 | 2.0 | 3.3 |
YS-90S-8 | 0.37 | 0.50 | 670 | 62.0 | 0.61 | 1.49 | 5.120 | 1.8 | 2.0 | 4.0 |
YS-90L-8 | 0.55 | 0.75 | 670 | 63.0 | 0.61 | 2.17 | 7.610 | 1.8 | 2.1 | 4.0 |
YE3 Series:
TYPE | RATED OUTPUT | RATED SPEED |
EFFICIENCY | POWER FOCTOR |
RATED CURRENT |
RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TOROUE | LOCKED ROTOR TORQUE | |
RATED TORQUE | RATED TORQUE | RATED CURRENT | ||||||||
KW | HP | rpm | η%(IE3) | cosφ | A | Nm | Ts/Tn | Tmax/Tn | IS/In | |
YE3-801-2 | 0.75 | 1.0 | 2880 | 80.7 | 0.82 | 1.72 | 2.49 | 2.3 | 2.3 | 7.0 |
YE3-802-2 | 1.10 | 1.5 | 2880 | 82.7 | 0.83 | 2.43 | 3.65 | 2.2 | 2.3 | 7.3 |
YE3-90S-2 | 1.50 | 2.0 | 2895 | 84.2 | 0.84 | 3.22 | 4.95 | 2.2 | 2.3 | 7.6 |
YE3-90L-2 | 2.20 | 3.0 | 2895 | 85.9 | 0.85 | 4.58 | 7.26 | 2.2 | 2.3 | 7.6 |
YE3-100L-2 | 3.00 | 4.0 | 2895 | 87.1 | 0.87 | 6.02 | 9.90 | 2.2 | 2.3 | 7.8 |
YE3-160L-2 | 18.50 | 25.0 | 2940 | 92.4 | 0.89 | 34.20 | 60.10 | 2.0 | 2.3 | 8.2 |
YE3-802-4 | 0.75 | 1.0 | 1420 | 82.5 | 0.75 | 1.84 | 5.04 | 2.3 | 2.3 | 6.6 |
YE3-90s-4 | 1.10 | 1.5 | 1445 | 84.1 | 0.76 | 2.61 | 7.27 | 2.3 | 2.3 | 6.8 |
YE3-90L-4 | 1.50 | 2.0 | 1445 | 85.3 | 0.77 | 3.47 | 9.91 | 2.3 | 2.3 | 7.0 |
YE3-100L1-4 | 2.20 | 3.0 | 1435 | 86.7 | 0.81 | 4.76 | 14.60 | 2.3 | 2.3 | 7.6 |
YE3-100L2-4 | 3.00 | 4.0 | 1435 | 87.7 | 0.82 | 6.34 | 20.00 | 2.3 | 2.3 | 7.6 |
YE3-112M-4 | 4.00 | 5.5 | 1440 | 88.6 | 0.82 | 8.37 | 26.50 | 2.2 | 2.3 | 7.8 |
YE3-132S-4 | 5.50 | 7.5 | 1460 | 89.6 | 0.83 | 11.20 | 36.00 | 2.0 | 2.3 | 7.9 |
YE3-132M-4 | 7.50 | 10.0 | 1460 | 90.4 | 0.84 | 15.00 | 49.10 | 2.0 | 2.3 | 7.5 |
YE3-160M-4 | 11.00 | 15.0 | 1465 | 91.4 | 0.85 | 21.50 | 71.70 | 2.2 | 2.3 | 7.7 |
YE3-160L-4 | 15.00 | 20.0 | 1465 | 92.1 | 0.86 | 28.80 | 97.80 | 2.2 | 2.3 | 7.8 |
YE3-180M-4 | 18.50 | 25.0 | 1470 | 92.6 | 0.86 | 35.30 | 120.20 | 2.0 | 2.3 | 7.8 |
YE3-180L-4 | 22.00 | 30.0 | 1470 | 93 | 0.86 | 41.80 | 142.90 | 2.0 | 2.3 | 7.8 |
YE3-90S-6 | 0.75 | 1.0 | 935 | 78.9 | 0.71 | 2.03 | 7.66 | 2.0 | 2.1 | 6.0 |
YE3-90L-6 | 1.10 | 1.5 | 945 | 81 | 0.73 | 2.83 | 11.10 | 2.0 | 2.1 | 6.0 |
YE3-100L-6 | 1.50 | 2.0 | 949 | 82.5 | 0.73 | 3.78 | 15.10 | 2.0 | 2.1 | 6.5 |
YE3-112M-6 | 2.20 | 3.0 | 955 | 84.3 | 0.74 | 5.36 | 22.00 | 2.0 | 2.1 | 6.6 |
YE3-132S-6 | 3.00 | 4.0 | 968 | 85.6 | 0.74 | 7.20 | 29.60 | 2.0 | 2.1 | 6.8 |
YE3-132M1-6 | 4.00 | 5.5 | 968 | 86.8 | 0.74 | 9.46 | 39.50 | 2.0 | 2.1 | 6.8 |
YE3-132M2-6 | 5.50 | 7.5 | 968 | 88 | 0.75 | 12.70 | 54.30 | 2.0 | 2.1 | 7.0 |
YE3-160M-6 | 7.50 | 10.0 | 970 | 89.1 | 0.79 | 16.20 | 73.80 | 2.0 | 2.1 | 7.0 |
YE3-160L-6 | 11.00 | 15.0 | 970 | 90.3 | 0.8 | 23.10 | 108.30 | 2.0 | 2.1 | 6.2 |
YE3-180L-6 | 18.50 | 20.0 | 975 | 91.2 | 0.81 | 30.90 | 146.90 | 2.0 | 2.1 | 7.3 |
YE4 Series:
OUTPUT | RATED CURRENT | ROTATE SPEED | EFFICIENCY | POWER FOCTOR | RATED TORQUE | LOCKED ROTOR TORQUE | LOCKED ROTOR CURRENT | MAXIMUM TORQUE | NOISE | |
TYPE | RATED TORQUE | RATED CURRENT | RATED TORQUE | |||||||
kW | A | r/min | Eff.%(IE4) | P.F | N.m | Tst | Ist | Tmax | dB(A) | |
TN | IN | TN | ||||||||
SYNCHRO-SPEED 3000r/min | ||||||||||
YE4-80M1-2 | 0.75 | 1.6 | 2895 | 83.5 | 0.83 | 2.47 | 2.2 | 8.5 | 2.3 | 62 |
YE4-80M2-2 | 1.1 | 2.4 | 2895 | 85.2 | 0.83 | 3.63 | 2.2 | 8.5 | 2.3 | 62 |
YE4-90S-2 | 1.5 | 3.1 | 2880 | 86.5 | 0.85 | 4.97 | 2.2 | 9.0 | 2.3 | 67 |
YE4-90L-2 | 2.2 | 4.4 | 2880 | 88.0 | 0.86 | 7.30 | 2.2 | 9.0 | 2.3 | 67 |
YE4-100L-2 | 3 | 5.9 | 2905 | 89.1 | 0.87 | 9.86 | 2.2 | 9.5 | 2.3 | 74 |
YE4-112M-2 | 4 | 7.7 | 2920 | 90.0 | 0.88 | 13.10 | 2.2 | 9.5 | 2.3 | 77 |
YE4-132S1-2 | 5.5 | 10.4 | 2945 | 90.0 | 0.88 | 17.80 | 2.0 | 9.5 | 2.3 | 79 |
YE4-132S2-2 | 7.5 | 14 | 2940 | 91.7 | 0.89 | 24.40 | 2.0 | 9.5 | 2.3 | 79 |
YE4-160M1-2 | 11 | 20.3 | 2965 | 92.6 | 0.89 | 35.40 | 2.0 | 9.5 | 2.3 | 81 |
YE4-160M2-2 | 15 | 27.5 | 2965 | 93.3 | 0.89 | 48.30 | 2.0 | 9.5 | 2.3 | 81 |
YE4-160L-2 | 18.5 | 33.7 | 2965 | 93.7 | 0.89 | 59.60 | 2.0 | 9.5 | 2.3 | 81 |
SYNCHRO-SPEED1500r/min | ||||||||||
YE4-80M1-4 | 0.55 | 1.4 | 1440 | 83.9 | 0.74 | 3.65 | 2.4 | 6.6 | 2.3 | 56 |
YE4-80M2-4 | 0.75 | 1.8 | 1440 | 85.7 | 0.74 | 4.97 | 2.3 | 8.5 | 2.3 | 56 |
YE4-90S-4 | 1.1 | 2.6 | 1445 | 87.2 | 0.75 | 7.27 | 2.3 | 8.5 | 2.3 | 59 |
YE4-90L-4 | 1.5 | 3.4 | 1445 | 88.2 | 0.76 | 9.91 | 2.3 | 9.0 | 2.3 | 59 |
YE4-100L1-4 | 2.2 | 4.7 | 1450 | 89.5 | 0.79 | 14.50 | 2.3 | 9.0 | 2.3 | 64 |
YE4-100L2-4 | 3 | 6.3 | 1450 | 90.4 | 0.8 | 19.80 | 2.3 | 9.5 | 2.3 | 64 |
YE4-112M-4 | 4 | 8.3 | 1460 | 91.1 | 0.8 | 26.20 | 2.3 | 9.5 | 2.3 | 65 |
YE4-132S-4 | 5.5 | 11.4 | 1475 | 91.1 | 0.8 | 35.60 | 2.0 | 9.5 | 2.3 | 71 |
YE4-132M-4 | 7.5 | 15.2 | 1470 | 92.6 | 0.81 | 48.70 | 2.0 | 9.5 | 2.3 | 71 |
YE4-160M-4 | 11 | 21.6 | 1470 | 93.3 | 0.83 | 71.50 | 2.0 | 9.5 | 2.3 | 73 |
YE4-160L-4 | 15 | 28.9 | 1470 | 93.9 | 0.84 | 97.40 | 2.0 | 9.5 | 2.3 | 73 |
SYNCHRO-SPEED1000r/min | ||||||||||
YE4-80M1-6 | 0.37 | 1.1 | 940 | 78.0 | 0.68 | 3.76 | 1.9 | 6.0 | 2.1 | 54 |
YE4-80M2-6 | 0.55 | 1.5 | 940 | 80.9 | 0.68 | 5.59 | 1.9 | 6.0 | 2.1 | 54 |
YE4-90S-6 | 0.75 | 2 | 950 | 82.7 | 0.7 | 7.54 | 2.1 | 7.5 | 2.1 | 57 |
YE4-90L-6 | 1.1 | 2.8 | 950 | 84.5 | 0.7 | 11.10 | 2.1 | 7.5 | 2.1 | 57 |
YE4-100L-6 | 1.5 | 3.7 | 960 | 85.9 | 0.71 | 14.90 | 2.1 | 7.5 | 2.1 | 61 |
YE4-112M-6 | 2.2 | 5.4 | 975 | 87.4 | 0.71 | 21.50 | 2.1 | 7.5 | 2.1 | 65 |
YE4-132S-6 | 3 | 7.2 | 985 | 88.6 | 0.71 | 29.10 | 2.0 | 7.5 | 2.1 | 69 |
YE4-132M1-6 | 4 | 9.4 | 985 | 89.5 | 0.72 | 38.80 | 2.0 | 8.0 | 2.1 | 69 |
YE4-132M2-6 | 5.5 | 12.8 | 980 | 90.5 | 0.72 | 53.60 | 2.0 | 8.0 | 2.1 | 69 |
YE4-160M-6 | 7.5 | 16.4 | 980 | 91.3 | 0.76 | 73.10 | 2.0 | 8.0 | 2.1 | 73 |
YE4-160L-6 | 11 | 23.5 | 980 | 92.3 | 0.77 | 107.00 | 2.0 | 8.5 | 2.1 | 73 |
YEJ 3000r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | STATIC BRAKE TCRQUE | BRAKE TIME |
RATED TORQUE | RATED TORQUE | DC | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | NM | S | |
YEJ-631-2 | 0.18 | 2800 | 65.0 | 0.80 | 0.53 | 0.61 | 2.2 | 2.2 | 3.5 | 0.10 |
YEJ-632-2 | 0.25 | 2800 | 68.0 | 0.81 | 0.69 | 0.85 | 2.2 | 2.2 | 3.5 | 0.10 |
YEJ-711-2 | 0.37 | 2830 | 70.0 | 0.81 | 0.99 | 1.25 | 2.2 | 2.2 | 4.0 | 0.10 |
YEJ-712-2 | 0.55 | 2830 | 73.0 | 0.82 | 1.40 | 1.86 | 2.2 | 2.3 | 4.0 | 0.10 |
YEJ-801-2 | 0.75 | 2840 | 75.0 | 0.83 | 1.83 | 2.52 | 2.2 | 2.3 | 7.5 | 0.10 |
YEJ-802-2 | 1.10 | 2840 | 77.0 | 0.84 | 2.55 | 3.70 | 2.2 | 2.3 | 7.5 | 0.10 |
YEJ-90S-2 | 1.50 | 2840 | 79.0 | 0.84 | 3.39 | 5.04 | 2.2 | 2.3 | 15 | 0.15 |
YEJ-90L-2 | 2.20 | 2840 | 81.0 | 0.85 | 4.80 | 7.40 | 2.2 | 2.3 | 15 | 0.15 |
YEJ-100L1-2 | 3.00 | 2860 | 83.0 | 0.87 | 6.31 | 10.00 | 2.2 | 2.3 | 30 | 0.15 |
YEJ-100L2-2 | 4.00 | 2880 | 85.0 | 0.88 | 8.22 | 13.30 | 2.2 | 2.3 | 40 | 0.15 |
YEJ-112M-2 | 5.50 | 2910 | 86.0 | 0.88 | 11.2 | 18.00 | 2.2 | 2.3 | 80 | 0.15 |
YEJ-132S-2 | 7.00 | 2910 | 87.0 | 0.88 | 15.1 | 24.60 | 2.2 | 2.3 | 80 | 0.15 |
YEJ-132M-2 | 11.00 | 2930 | 88.0 | 0.89 | 21.3 | 35.90 | 2.2 | 2.3 | 150 | 0.30 |
YEJ-160M-2 | 15.00 | 2930 | 89.0 | 0.89 | 28.8 | 48.90 | 2.2 | 2.2 | 150 | 0.30 |
YEJ-160L-2 | 18.50 | 2935 | 90.0 | 0.90 | 34.7 | 60.20 | 2.2 | 2.2 | 150 | 0.30 |
YEJ-180M-2 | 22.00 | 2935 | 90.0 | 0.90 | 41.3 | 71.60 | 2.2 | 2.2 | 200 | 0.30 |
YEJ 1500r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | STATIC BRAKE TCRQUE | BRAKE TIME |
RATED TORQUE | RATED TORQUE | DC | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | NM | S | |
YEJ-631-4 | 0.12 | 1360 | 57.0 | 0.72 | 0.44 | 0.84 | 2.2 | 2.0 | 3.5 | 0.10 |
YEJ-632-4 | 0.18 | 1360 | 60.0 | 0.73 | 0.62 | 1.26 | 2.2 | 2.0 | 3.5 | 0.10 |
YEJ-711-4 | 0.25 | 1375 | 65.0 | 0.74 | 0.79 | 1.74 | 2.2 | 2.0 | 4.0 | 0.10 |
YEJ-712-4 | 0.37 | 1375 | 67.0 | 0.75 | 1.12 | 2.57 | 2.2 | 2.0 | 4.0 | 0.10 |
YEJ-801-4 | 0.55 | 1405 | 71.0 | 0.75 | 1.57 | 3.74 | 2.2 | 2.4 | 7.5 | 0.10 |
YEJ-802-4 | 0.75 | 1405 | 73.0 | 0.76 | 2.02 | 5.10 | 2.2 | 2.4 | 7.5 | 0.10 |
YEJ-90S-4 | 1.10 | 1445 | 75.0 | 0.77 | 2.82 | 7.27 | 2.2 | 2.3 | 15 | 0.15 |
YEJ-90L-4 | 1.50 | 1445 | 78.0 | 0.79 | 3.7 | 9.91 | 2.2 | 2.3 | 15 | 0.15 |
YEJ-100L1-4 | 2.20 | 1440 | 80.0 | 0.81 | 5.16 | 14.60 | 2.2 | 2.3 | 30 | 0.15 |
YEJ-100L2-4 | 3.00 | 1440 | 82.0 | 0.82 | 6.78 | 19.90 | 2.2 | 2.3 | 30 | 0.15 |
YEJ-112M-4 | 4.00 | 1440 | 84.0 | 0.82 | 8.82 | 26.50 | 2.2 | 2.3 | 40 | 0.15 |
YEJ-132S-4 | 5.50 | 1440 | 85.0 | 0.83 | 11.7 | 36.50 | 2.2 | 2.3 | 80 | 0.15 |
YEJ-132M-4 | 7.50 | 1440 | 87.0 | 0.84 | 15.6 | 49.70 | 2.2 | 2.3 | 80 | 0.15 |
YEJ-160M-4 | 11.00 | 1450 | 88.0 | 0.85 | 21.3 | 72.40 | 2.2 | 2.2 | 150 | 0.30 |
YEJ-160L-4 | 15.00 | 1450 | 89.0 | 0.85 | 30.1 | 98.80 | 2.2 | 2.2 | 150 | 0.30 |
YEJ-180M-4 | 18.50 | 1455 | 90.5 | 0.86 | 36.5 | 121.40 | 2.2 | 2.2 | 150 | 0.30 |
YEJ-180L-4 | 22.00 | 1455 | 91.0 | 0.86 | 43.1 | 144.40 | 2.0 | 2.2 | 200 | 0.30 |
YEJ 1000r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | STATIC BRAKE TCRQUE | BRAKE TIME |
RATED TORQUE | RATED TORQUE | DC | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | NM | S | |
YEJ-711-6 | 0.18 | 900 | 56.0 | 0.66 | 0.71 | 19.10 | 1.9 | 2.0 | 4.0 | 0.10 |
YEJ-712-6 | 0.25 | 900 | 59.0 | 0.68 | 0.95 | 2.65 | 1.9 | 2.0 | 4.0 | 0.10 |
YEJ-801-6 | 0.37 | 910 | 62.0 | 0.70 | 1.30 | 3.88 | 1.9 | 2.0 | 7.5 | 0.10 |
YEJ-802-6 | 0.55 | 910 | 65.0 | 0.72 | 1.79 | 5.77 | 1.9 | 2.1 | 7.5 | 0.10 |
YEJ-90S-6 | 0.75 | 930 | 69.0 | 0.72 | 2.26 | 7.70 | 2.1 | 2.1 | 15 | 0.15 |
YEJ-90L-6 | 1.10 | 940 | 72.0 | 0.73 | 3.14 | 11.20 | 2.1 | 2.1 | 15 | 0.15 |
YEJ-100L-6 | 1.50 | 940 | 76.0 | 0.76 | 3.95 | 15.20 | 2.2 | 2.1 | 30 | 0.15 |
YEJ-112M-6 | 2.20 | 96o | 79.0 | 0.76 | 5.57 | 21.90 | 2.2 | 2.1 | 40 | 0.15 |
YEJ-132S-6 | 3.00 | 960 | 81.0 | 0.76 | 7.40 | 29.80 | 2.2 | 2.1 | 80 | 0.15 |
YEJ-132M1-6 | 4.00 | 960 | 82.0 | 0.76 | 9.63 | 39.80 | 2.2 | 2.1 | 80 | 0.15 |
YEJ-132M2-6 | 5.50 | 960 | 84.0 | 0.77 | 12.90 | 54.70 | 2.2 | 2.1 | 150 | 0.30 |
YEJ-160M-6 | 7.50 | 970 | 86.0 | 0.77 | 17.00 | 73.80 | 1.8 | 2.1 | 150 | 0.30 |
YEJ-160L-6 | 11.00 | 970 | 87.5 | 0.78 | 24.30 | 108.30 | 1.9 | 2.1 | 150 | 0.30 |
YEJ-180L-6 | 15.00 | 970 | 89.0 | 0.81 | 31.60 | 147.70 | 2.1 | 2.1 | 200 | 0.30 |
YVP 3000r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | FREOUENCY CONVERSION BLOWER | ||
RATED TORQUE | RATED TORQUE | VOLTAGEV | SPEED | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | THREE PHASE | SINGLE PHASE | RPM | |
YVP-631-2 | 0.18 | 2800 | 65.0 | 0.80 | 0.53 | 0.61 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-632-2 | 0.25 | 2800 | 68.0 | 0.81 | 0.69 | 0.85 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-711-2 | 0.37 | 2830 | 70.0 | 0.81 | 0.99 | 1.25 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-712-2 | 0.55 | 2830 | 73.0 | 0.82 | 1.40 | 1.86 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-801-2 | 0.75 | 2840 | 75.0 | 0.83 | 1.83 | 2.52 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-802-2 | 1.10 | 2840 | 77.0 | 0.85 | 2.55 | 3.70 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-90S-2 | 1.50 | 2840 | 79.0 | 0.85 | 3.39 | 5.04 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-90L-2 | 2.20 | 2840 | 81.0 | 0.86 | 4.80 | 7.40 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-100L-2 | 3.00 | 2860 | 83.0 | 0.87 | 6.31 | 10.0 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-112M-2 | 4.00 | 2880 | 84.0 | 0.88 | 8.22 | 13.3 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-132S1-2 | 5.50 | 2910 | 85.0 | 0.88 | 11.2 | 18.0 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-132S2-2 | 7.50 | 2910 | 86.0 | 0.88 | 15.1 | 24.6 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-160M1-2 | 11.0 | 2930 | 88.0 | 0.89 | 21.3 | 35.9 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-160M2-2 | 15.0 | 2930 | 89.0 | 0.89 | 28.8 | 48.9 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-160L-2 | 18.5 | 2935 | 90.0 | 0.90 | 34.7 | 60.2 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-180M-2 | 22.0 | 2935 | 90.0 | 0.90 | 41.3 | 71.6 | 2.0 | 2.3 | 380 | 220 | 2800 |
YVP 1500r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | FREOUENCY CONVERSION BLOWER | ||
RATED TORQUE | RATED TORQUE | VOLTAGEV | SPEED | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | THREE PHASE | SINGLE PHASE | RPM | |
YVP-631-4 | 0.12 | 1360 | 57.0 | 0.72 | 0.44 | 0.84 | 2.2 | 2.0 | 380 | 220 | 2800 |
YVP-632-4 | 0.18 | 1360 | 60.0 | 0.73 | 0.62 | 1.26 | 2.2 | 2.0 | 380 | 220 | 2800 |
YVP-711-4 | 0.25 | 1375 | 65.0 | 0.74 | 0.79 | 1.74 | 2.2 | 2.0 | 380 | 220 | 2800 |
YVP-712-4 | 0.37 | 1375 | 67.0 | 0.75 | 1.12 | 2.57 | 2.2 | 2.0 | 380 | 220 | 2800 |
YVP-801-4 | 0.55 | 1405 | 71.0 | 0.75 | 1.57 | 3.74 | 2.2 | 2.4 | 380 | 220 | 2800 |
YVP-802-4 | 0.75 | 1405 | 73.0 | 0.77 | 2.02 | 5.10 | 2.2 | 2.4 | 380 | 220 | 2800 |
YVP-90S-4 | 1.10 | 1445 | 75.0 | 0.79 | 2.82 | 7.27 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-90L-4 | 1.50 | 1445 | 78.0 | 0.79 | 3.70 | 9.91 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-100L1-4 | 2.20 | 1440 | 80.0 | 0.81 | 5.16 | 14.60 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-100L2-4 | 3.00 | 1440 | 82.0 | 0.82 | 6.78 | 19.90 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-112M-4 | 4.00 | 1440 | 84.0 | 0.82 | 8.82 | 26.50 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-132S-4 | 5.50 | 1440 | 85.0 | 0.84 | 11.70 | 36.50 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-132M-4 | 7.50 | 1440 | 87.0 | 0.84 | 15.60 | 49.70 | 2.2 | 2.3 | 380 | 220 | 2800 |
YVP-160M-4 | 11.0 | 1450 | 88.0 | 0.85 | 21.30 | 72.40 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-160L-4 | 15.0 | 1450 | 89.0 | 0.85 | 30.10 | 98.80 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-180M-4 | 18.5 | 1455 | 90.5 | 0.86 | 36.50 | 121.40 | 2.2 | 2.2 | 380 | 220 | 2800 |
YVP-180L-4 | 22.0 | 1455 | 91.0 | 0.86 | 43.10 | 144.40 | 2.0 | 2.2 | 380 | 220 | 2800 |
YVP 1000r/min 380V 50Hz:
TYPE | RATED OUTPUT | RATED SPEED | EFFICENCY | POWER FOCTOR | RATED CURRENT | RATED TORQUE | LOCKED ROTOR TORQUE | MAXIMUM TORQUE | FREOUENCY CONVERSION BLOWER | ||
RATED TORQUE | RATED TORQUE | VOLTAGEV | SPEED | ||||||||
KW | rpm | η% | COSφ | A | Nm | Ts/Tn | Tmax/Tn | THREE PHASE | SINGLE PHASE | RPM | |
YVP-711-6 | 0.18 | 900 | 58.0 | 0.66 | 0.71 | 1.91 | 1.9 | 2.0 | 380 | 220 | 2800 |
YVP-712-6 | 0.25 | 900 | 59.0 | 0.68 | 0.95 | 2.65 | 1.9 | 2.0 | 380 | 220 | 2800 |
YVP-801-6 | 0.37 | 910 | 62.0 | 0.70 | 1.30 | 3.88 | 1.9 | 2.0 | 380 | 220 | 2800 |
YVP-802-6 | 0.55 | 910 | 65.0 | 0.72 | 1.79 | 5.77 | 1.9 | 2.1 | 380 | 220 | 2800 |
YVP-90S-6 | 0.75 | 930 | 70.0 | 0.72 | 2.26 | 7.70 | 2.1 | 2.1 | 380 | 220 | 2800 |
YVP-90L-6 | 1.10 | 940 | 73.0 | 0.73 | 3.14 | 11.2 | 2.1 | 2.1 | 380 | 220 | 2800 |
YVP-100L-6 | 1.50 | 940 | 76.0 | 0.76 | 3.95 | 15.2 | 2.2 | 2.1 | 380 | 220 | 2800 |
YVP-112M-6 | 2.20 | 960 | 79.0 | 0.76 | 5.57 | 21.9 | 2.2 | 2.1 | 380 | 220 | 2800 |
YVP-132S-6 | 3.00 | 960 | 81.0 | 0.76 | 7.40 | 29.8 | 2.2 | 2.1 | 380 | 220 | 2800 |
YVP-132M1-6 | 4.00 | 960 | 83.0 | 0.76 | 9.63 | 39.8 | 2.2 | 2.1 | 380 | 220 | 2800 |
YVP-132M2-6 | 5.50 | 960 | 84.0 | 0.77 | 12.9 | 54.7 | 2.2 | 2.1 | 380 | 220 | 2800 |
YVP-160M-6 | 7.50 | 970 | 86.0 | 0.78 | 17.0 | 73.8 | 1.8 | 2.1 | 380 | 220 | 2800 |
YVP-160L-6 | 11.0 | 970 | 87.0 | 0.79 | 24.3 | 108.3 | 1.9 | 2.1 | 380 | 220 | 2800 |
YVP-180L-6 | 15.0 | 970 | 89.0 | 0.81 | 31.6 | 147.7 | 2.1 | 2.1 | 380 | 220 | 2800 |
Company Profile
TLWERK, established by the R&D, production and sales team with more than 10 years of technical experience, is a professional trade company.
We focus on the R&D, technology and sales services of induction motors and motor power source systems, especially for the customized development of products according to the specific application requirements of customers.
The products are produced and tested by our professional motor manufacturers and related motor system manufacturers in the partnership.
The developed three-phase asynchronous motor series are: YS/MS, YL/ML, YE3, YE4, YEJ, YVP and permanent magnet motors.
Our products have got a good domestic market and a good fame in more than 30 provinces and cities in China, and now gradually expand the international market.
We have our own experienced R&D team, modern production lines and high-precision testing equipment. The manufacturer strictly implements the ISO9001-2015 quality management system, and all products have been inspected, and have obtained national CCC certification and international CE certification, as well as other relevant international certifications. Our motor products are widely used in different fields such as reducers, hydraulic equipment, lifting equipment, fans, wind power, home appliances, food, clothing, papermaking, packaging, ceramics, printing, chemical industry, animal husbandry machinery, woodworking machinery, agriculture and water conservancy.
Production & Workshop
We adhere to the business philosophy of “Life, based on quality; Trust, based on honesty; Win-win cooperation”, and insists on giving back to all customers with high-quality products and comprehensive services!
Certifications
Packaging & Shipping
FAQ
1.How about your MOQ and lead time?
Both MOQ and lead time depends on specific products. Generally speaking, it cost 10-30 days.
2.Can I get sample?
Yes. We offer sample motor.
3.Is customized service available?
OEM & ODM both are available. Please inform us with output power, speed rpm, output torque, using voltage and application range.
4. What is your payment term?
30% T/T in advance, 70% balance before shipment
30% T/T in advance, 70% balance 30 days after BL date by ocean, 15 days after AWB date by air, after a long-term stable cooperation.
5. What about warranty?
One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.
6.Why us?
* Professional factory for Electric Motor in China
*Safety / Energy Consumption / Superior Life
* Full of export experiences.
* 100% tested before delivery
* A complete set of motor solutions can be provided.
* Perfect performance, low noise, slight vibration, reliable running, good appearance, small volume, light weight and easy maintenance.
* CE/ISO Approved
Before Sale | After Sale | ||
1 | Sample Confirmation | 1 | Comprehensive service with separate after-sale team |
2 | Providing information consulting and technical guidance. | 2 | Satisfied solution while any problem identified. |
3 | Packaging can be customized. | 3 | Exclusive and unique solution provided by professional engineers. |
4 | Reply to your enquiry in 24 working hours. | 4 | New craft, new technology and other related advisory services. |
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Application: | Universal |
---|---|
Speed: | Constant Speed |
Number of Stator: | Single-Phase and Three-Phase |
Samples: |
US$ 50/Piece
1 Piece(Min.Order) | Order Sample |
---|
Customization: |
Available
|
|
---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: |
|
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
editor by CX 2024-04-23
China wholesaler Tyl (Liquid Cooling) Series Permanent Magnet Synchronous Servo Motors supplier
Product Description
Product Description
TYL series (liquid-cooled) permanent magnet synchronous servo motor is a product completely independently developed by our company. It is mainly suitable for occasions where the environment is dusty, the motor volume is relatively compact, or the motor temperature rise is required to be relatively low. For example, profile stretching and extrusion situations, metal cable drawing situations, ceramic production workshops, die-casting workshops, wood pellet machines, grinding machines, etc.
The power range of this series of motors is: 75-560kw.
This series of products is recommended to be cooled with oil. You can also use automobile antifreeze for cooling, but you cannot directly use untreated tap water for cooling.
Application Condition
K uses rings: general that do not contain flammable, volatile or corrosive gases
1.Place and machinery without independent requirements
2. Ring temperature: varies with seasons, but not more than 40t
3. Hai Yu: no more than 000m
4. Installation structure: IMB35, IMB5
5. Protection level: IP54
6. Surface paint: black
Technical Data
Note:This series of products is recommended to be cooled with oil. You can also use automobile antifreeze for cooling, but you cannot directly use untreated tap water for cooling.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Application: | Industrial |
---|---|
Speed: | High Speed |
Number of Stator: | Three-Phase |
Function: | Driving |
Casing Protection: | Protection Type |
Number of Poles: | 8 |
Customization: |
Available
|
|
---|
editor by CX 2024-04-08
China supplier Ec Brushless AC Synchronous Permanent Magnet Electric Fridge Fan Motors vacuum pump connector
Product Description
Product Description
EC MOTOR for Refrigeration is a high-performance electronically commutated motor, specifically designed for refrigeration and air conditioning systems. lt provides superior efficiency, precise control, and long-lasting reliability for demanding applications.
Features:
1) High Efficiency:
The EC MOTOR for Refrigeration has a brushless DC design that provides up to 70% efficiency, which is significantly higher than traditional AC motors.The motor’s integrated electronic control system continually monitors operating conditions and adjusts the motor’s speed, resulting in reduced energy consumption, lower operating costs, and longer service life.
2) Precise Control:
The motor has a smooth, continuous speed control that enables precise temperature and humidity regulation. The EC MOTOR for Refrigeration can operate at variable speeds to match system demand, making it an ideal choice forenergy-efficient systems.
3) Reduced Noise and Vibration:
The brushless DC design and electronic control systerresult in less noise and vibration compared to traditional AC motors. This makes it anexcellent choice for quiet environments
4) Compact Design:
The compact design of the EC MOTOR for Refrigeration provides a high power-to-size ratio, which makes it an ideal choice for space-constrained applications.
Specifications:
1) Voltage:
The motor operates on a range of voltages, from 100V to 240V.
2) Speed:
The motor’s speed can be controlled between 300RPM to 1800RPM depending on the application.
3) Control:
The motor features an integrated electronic control system that provides precise speed control and system monitoring.
4) Operating Temperature:
The motor can operate in a temperature range from -40°C to +50°C
Overall, the EC MOTOR for Refrigeration is a highly efficient, reliable. and precise motor designed to meet the demands of refrigeration and air conditioning applications. lts superior performance makes it an ideal choice for OEMs and system integrators looking to improve system efficiency and reliability.
As long as you are a manufacturer of super-market refrigeration equipements, or beverage cabinets, or beer coolers etc, you will be in need of our EC Brushless Motor for Fan.
Product Parameters
MDAC4810A EC Brushless Motor Parameters:
MODEL | Voltage V |
Maximum load | SPEED RPM |
Minimum noise dB(A) | Minimum vibration mm/s | Maximum power W |
Maximum efficiency % |
MDAC4810A | 100-240V | 230 34° | 300-1800 | 38 | 1.1 | 20 | 70 |
LOAD/SPEED | 200mm blade | 230mm blade | ||
28° | 34° | 28° | 34° | |
1300RPM | V | V | V | V |
1500RPM | V | V | V | X |
1800RPM | V | X | X | X |
Technical Parameter | |
Nominal voltage range | 220-240VAC,100-240VAC,50/60Hz |
Rotation speed range | 300- 1800 rpm |
Material | PBT |
Airflow direction | Air exhaust or airintake (depending on impeller) |
Direction of rotation | CCW(view on drive end) |
Degree of protection | IP65 |
Insulation class | “B” VD, “F” UL |
Installation position | Any |
Mode of operation | Continuous operation (S1) |
Bearings | Maintenance-free ball bearing system |
Motor protection | By electronics |
Electrical hook-up | Power cables |
Protection class | II(without grounding conductor) |
Approvals | CCC; EAC;VDE,EN 6571-2-24,EN 6571-2-89,EN 6571-1 |
Fitting of attachments | Guard grille and wall ring are attached to the projecting thread ends on the |
Mounting of axial impeller | A plastic adapter with catching peg and M4 screw is used to secure the impeller on the motor shaft |
Ambient temperature | -40ºC-50ºC |
We continuously improve and pursue products that are more energy-efficient, stable, popular, and environmentally friendly. Compared to traditional covered pole motor products, EC has obvious advantages in high-efficiency and energy-saving electrodes, specifically:
Comparison details of MDAC4810A and 10W shaded pole motors:
1) Energy Saving
It’s power consumption is around 1/3 of Shade-pole motor to meet the same function.
Such a siginificant energy saving is what your customers always wanted, considering the huge power consumption where your equiment is used for.
It’s also meeting high energy standard of North American and European market.
2) Job Saving
We have 2 models of EC Motor that are enough to cover almost all 7 models of Shade-pole motor for different refrigeration equipements, because EC Motor is designed to be speed adjustable.
– Adjustable speed saves your job of model selection for both purchaing team and technical team.
– Long life saves your job of after-sales.
– Energy sameing saves your job of explaining to your buyers.
– Wide voltage range saves your marketing policy to different markets.
Below listed the comparasion between our EC Motor and regular Shade-pole Motor:
EC Motor 4810A | Shade-Plole Motor 10W | |
Input Power | 15W | 40W |
Out Power | 9.5W | 10W |
Voltage | 100-240V | 110V or 220V |
Height of The Motor | 62mm +/-1 | 85mm +/-1 |
Noise | 39.5dBA | 55dBA |
Motor Life | 8~10years | 3~5years |
Bearing | Ball bearing | Sleeve bearing |
Efficient | up to 70% | Max 18% |
Speed | 300~1800rpm | 1300rpm |
Certificate | UL, VDE, CE, CCC, EX, Rohs | UL, VDE, CE, CCC, EX, Rohs |
Protect Level | IP65 | IP42 |
→Click to View More EC Motors Products!!!
Company Profile
We have our own design, research and development, testing equipment, and production line. The cost-effectiveness and after-sales service of our products are guaranteed, and we can provide technical support and customized services!
Exhibition
Certifications
With abundant technique force,we have our own researching, developing, manufacturing, inspecting and testingcenters, and imported the international advanced high-tech equipments. Our company has passed the ISO9001,ISO14001,OHS18001 international management system certificates. The products have got UL,ETL,CE,CB,and CCC certificates. Our products are not only selling strongly in more than 30 provincesand municipality,but also largely exporting to Europe,America,Australia,Middle East, Africa and South Asia. We have won an excellent reputation from the customers and friends by our product quality,price versus performance ratio and service.
FAQ
Q1: Are you a manufacturer or trader?
A1: ZHangZhoug Maidi Refrigeration Technology Co., Ltd. is a Hi-tech enterprise. We own the standard plant and office building which covering 21, 000 square meters. With abundant technique force, we have our own researching, developing, manufacturing, inspecting and testing centers, and imported the international advanced equipments.
Q2: How to replace refrigerator ec motor?
A2: We have a professional team of engineers who provide technical support and online guidance on product installation and replacement.
Q3: How do you ensure quality?
A3: We have a dedicated product research and testing center with authoritative quality management system certification: ISO9001/ISO14001/OHS18001.
Q4: How much does a refrigeration part cost?
A4: Factory price for you, not cheapest but the lowest at the same quality.
Application: | Refrigerators/Beverage Cabinets/Ice Maker, etc. |
---|---|
Speed: | Variable Speed |
Number of Stator: | Three-Phase |
Samples: |
US$ 15/Piece
1 Piece(Min.Order) | Order Sample |
---|
Customization: |
Available
|
|
---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: |
|
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
editor by CX 2023-10-20